Voltage Drop Formula:
From: | To: |
Definition: This calculator estimates the voltage drop in solar wiring systems based on wire properties and current flow.
Purpose: It helps solar installers and electrical engineers ensure proper voltage levels throughout PV systems.
The calculator uses the formula:
Where:
Explanation: The formula calculates the voltage lost due to resistance in the wire over a specific length.
Details: Proper voltage drop estimation ensures system efficiency, prevents power loss, and maintains equipment performance.
Tips: Enter the wire resistivity (default 1.68×10⁻⁸ ohm-m for copper), length in meters, current in amps, and cross-sectional area in m². All values must be > 0.
Q1: Why is there a factor of 2 in the formula?
A: The factor of 2 accounts for the round-trip path of current (both positive and negative conductors).
Q2: What's a typical resistivity value for copper?
A: Copper has resistivity of about 1.68×10⁻⁸ ohm-m at 20°C (default value in calculator).
Q3: How does wire size affect voltage drop?
A: Larger wire (greater cross-sectional area) reduces voltage drop for the same current and length.
Q4: What's an acceptable voltage drop for solar systems?
A: Typically less than 2% of system voltage for DC circuits to maintain efficiency.
Q5: Does temperature affect the calculation?
A: Yes, resistivity changes with temperature. For precise calculations, use resistivity at operating temperature.