Voltage Drop Calculator

HomeDC & solar

1,000 watt inverter cable size

A 1,000 W inverter draws about 98 A from a 12 V battery at full output, 49 A at 24 V and 25 A at 48 V. Here is the cable and fuse for each.

W
One way, battery to inverter. Keep it as short as you can.
85% is a fair figure for full load; check the spec sheet.
%
%

Battery cable

Fill in the circuit, then press the button.

1,000 W inverter cable chart

BatteryInput currentFuse3 ft5 ft10 ft
12 V98 A125 A2 AWG2 AWG1 AWG
24 V49 A70 A6 AWG6 AWG6 AWG
48 V25 A35 A8 AWG8 AWG8 AWG

85% efficiency at nominal battery voltage. Copper, 90 °C ampacity at 125% of input current, 3% drop, one-way length. A battery near cutoff draws about 14% more.

Choosing the system voltage

Above about 2,000 W, 12 V cables become heavy and expensive and the connections run warm. At 1,000 W, 12 V is still workable with short cables. Surge ratings, often twice the continuous rating for a few seconds, are covered by the fuse's time delay rather than the cable.

Common questions

What size fuse for a 1000 W inverter on 12 V?

About 125 A, which is 125% of the 98 A full-load input current. Check the inverter manual for its maximum.

Can I use 4 AWG for a 1000 W inverter?

4 AWG copper is rated 95 A at 90 °C. At 12 V the inverter needs about 123 A of ampacity, so 4 AWG is too small; it works only at 24 V or 48 V where the current is lower.

Sources

  • NFPA 70, National Electrical Code, 2023 edition (https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70)
  • ABYC E-11, AC and DC Electrical Systems on Boats (https://abycinc.org/)