Voltage Drop Calculator

HomeCircuits

2 HP well pump wire size

A 2 HP 230 V pump has a full-load current of 12 A in NEC Table 430.248. The real limit is usually length: the cable runs down the well, so check the total.

One way from the panel to the motor. Enter 0 to skip voltage drop.
%
Used for voltage drop. Leave blank to use the NEC table current.
A

Pump circuit

Fill in the circuit, then press the button.

Maximum length for 2 HP at 230 V

CableLength to motor
14 AWG152 ft
12 AWG242 ft
10 AWG386 ft
8 AWG615 ft
6 AWG975 ft
4 AWG1,555 ft

5% drop at the NEC full-load current of 12 A. Pump makers publish their own charts based on service-factor amps, which are higher; use them where you can.

Length is from the pressure switch or control box to the motor: the horizontal run plus the pump setting depth.

Circuit

PartSize
Branch-circuit wire (125%)14 AWG
Maximum breaker (250%)30 A
Typical breaker25 A

Use the control box or pump manual's breaker size when it gives one.

Common questions

How far can I run 12 gauge to a 2 HP pump?

About 242 ft at 230 V and 5% drop, based on the table current. Service-factor amps can cut that by 20% or more.

Sources

  • NFPA 70, National Electrical Code, 2023 edition (https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70)