Marine wire size calculator
ABYC E-11 measures conductor length as the full round trip and sets two limits: 3% for critical circuits and 10% for the rest. Enter your circuit.
Wire size
Fill in the circuit, then press the button.
12 V boat wire, 3% critical circuits
| Amps | 10 ft | 20 ft | 30 ft | 40 ft | 60 ft | 80 ft |
|---|---|---|---|---|---|---|
| 5 A | 16 AWG | 14 AWG | 12 AWG | 12 AWG | 10 AWG | 8 AWG |
| 10 A | 14 AWG | 12 AWG | 10 AWG | 8 AWG | 6 AWG | 6 AWG |
| 15 A | 12 AWG | 10 AWG | 8 AWG | 6 AWG | 4 AWG | 4 AWG |
| 20 A | 12 AWG | 8 AWG | 6 AWG | 6 AWG | 4 AWG | 2 AWG |
| 30 A | 10 AWG | 6 AWG | 4 AWG | 4 AWG | 2 AWG | 1 AWG |
| 50 A | 8 AWG | 4 AWG | 2 AWG | 2 AWG | 1/0 AWG | 2/0 AWG |
Round-trip length. Resistance at 30 °C. ABYC requires 16 AWG minimum for most boat wiring.
12 V boat wire, 10% non-critical
| Amps | 10 ft | 20 ft | 30 ft | 40 ft | 60 ft | 80 ft |
|---|---|---|---|---|---|---|
| 5 A | 16 AWG | 16 AWG | 16 AWG | 16 AWG | 14 AWG | 14 AWG |
| 10 A | 16 AWG | 16 AWG | 14 AWG | 14 AWG | 12 AWG | 10 AWG |
| 15 A | 16 AWG | 14 AWG | 12 AWG | 12 AWG | 10 AWG | 8 AWG |
| 20 A | 16 AWG | 14 AWG | 12 AWG | 10 AWG | 8 AWG | 8 AWG |
| 30 A | 14 AWG | 12 AWG | 10 AWG | 8 AWG | 8 AWG | 6 AWG |
| 50 A | 12 AWG | 10 AWG | 8 AWG | 6 AWG | 4 AWG | 4 AWG |
Use tinned, fine-stranded marine cable (Type 3 stranding), and check the size against the E-11 ampacity tables for the insulation and whether the wire runs in the engine room.
Common questions
Why does marine wire use round-trip length?
ABYC tables count the total conductor length in the circuit, out and back, which is the same physics as doubling the one-way length.
What is the minimum wire size on a boat?
16 AWG for general wiring, with 18 AWG allowed in some bundled cases and inside panels.
Related calculators
Sources
- ABYC E-11, AC and DC Electrical Systems on Boats (https://abycinc.org/)