Voltage Drop Calculator

HomeDC & solar

Marine wire size calculator

ABYC E-11 measures conductor length as the full round trip and sets two limits: 3% for critical circuits and 10% for the rest. Enter your circuit.

A
Positive out to the load plus the negative back to the source.
ft

Wire size

Fill in the circuit, then press the button.

12 V boat wire, 3% critical circuits

Amps10 ft20 ft30 ft40 ft60 ft80 ft
5 A16 AWG14 AWG12 AWG12 AWG10 AWG8 AWG
10 A14 AWG12 AWG10 AWG8 AWG6 AWG6 AWG
15 A12 AWG10 AWG8 AWG6 AWG4 AWG4 AWG
20 A12 AWG8 AWG6 AWG6 AWG4 AWG2 AWG
30 A10 AWG6 AWG4 AWG4 AWG2 AWG1 AWG
50 A8 AWG4 AWG2 AWG2 AWG1/0 AWG2/0 AWG

Round-trip length. Resistance at 30 °C. ABYC requires 16 AWG minimum for most boat wiring.

12 V boat wire, 10% non-critical

Amps10 ft20 ft30 ft40 ft60 ft80 ft
5 A16 AWG16 AWG16 AWG16 AWG14 AWG14 AWG
10 A16 AWG16 AWG14 AWG14 AWG12 AWG10 AWG
15 A16 AWG14 AWG12 AWG12 AWG10 AWG8 AWG
20 A16 AWG14 AWG12 AWG10 AWG8 AWG8 AWG
30 A14 AWG12 AWG10 AWG8 AWG8 AWG6 AWG
50 A12 AWG10 AWG8 AWG6 AWG4 AWG4 AWG

Use tinned, fine-stranded marine cable (Type 3 stranding), and check the size against the E-11 ampacity tables for the insulation and whether the wire runs in the engine room.

Common questions

Why does marine wire use round-trip length?

ABYC tables count the total conductor length in the circuit, out and back, which is the same physics as doubling the one-way length.

What is the minimum wire size on a boat?

16 AWG for general wiring, with 18 AWG allowed in some bundled cases and inside panels.

Sources

  • ABYC E-11, AC and DC Electrical Systems on Boats (https://abycinc.org/)