Charge controller to battery wire size
The controller's output is its rated charging current, often 20 to 100 A at battery voltage. Keep this run short and the drop under 2% so the controller reads battery voltage accurately.
Wire size
Fill in the circuit, then press the button.
Controller output wire, 2% drop
| Controller | 12 V, 5 ft | 24 V, 5 ft | 48 V, 10 ft |
|---|---|---|---|
| 20 A | 10 AWG | 12 AWG | 12 AWG |
| 30 A | 8 AWG | 10 AWG | 10 AWG |
| 40 A | 8 AWG | 8 AWG | 8 AWG |
| 60 A | 6 AWG | 6 AWG | 6 AWG |
| 80 A | 4 AWG | 4 AWG | 4 AWG |
| 100 A | 3 AWG | 3 AWG | 3 AWG |
Copper, 90 °C ampacity at 125% of the controller rating.
Protection
Put a DC-rated fuse or breaker between the controller and the battery, sized at about 125% of the controller's output rating unless the manual says otherwise.
Common questions
What size wire for a 40 A charge controller?
At 12 V and 5 ft, 8 AWG copper.
Related calculators
Sources
- NFPA 70, National Electrical Code, 2023 edition (https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70)