DC-DC charger wire size
A DC-DC charger draws more current on its input than it delivers, because it boosts voltage. A 40 A charger often pulls about 50 A from the alternator side. Enter the input current.
Input cable
Fill in the circuit, then press the button.
Input cable by charger size
| Charger output | Input current (approx.) | 10 ft | 15 ft | 20 ft |
|---|---|---|---|---|
| 20 A | 25 A | 6 AWG | 4 AWG | 4 AWG |
| 25 A | 31 A | 6 AWG | 4 AWG | 3 AWG |
| 40 A | 50 A | 4 AWG | 2 AWG | 1 AWG |
| 50 A | 62 A | 3 AWG | 1 AWG | 1/0 AWG |
Copper, 90 °C, 3% drop. Low input voltage makes many chargers throttle back, which is why drop matters here.
Install notes
Fuse both ends of a long cable that connects two batteries, since either battery can feed a fault. Most manufacturers list cable sizes by length in their manuals; follow those first.
Common questions
Why is the input current higher than the output?
The charger raises the voltage to charge correctly. Power in equals power out plus losses, so lower input voltage means higher input current.
Related calculators
Sources
- ABYC E-11, AC and DC Electrical Systems on Boats (https://abycinc.org/)