200 watt solar panel wire size
A typical 200 W panel lists about Isc 11.5 A, Vmp 20.5 V. Your panel's label may differ, so the calculator uses whatever you enter.
PV wire
Fill in the circuit, then press the button.
200 W panel wiring options
| Layout | Voltage | Current | Ampacity needed |
|---|---|---|---|
| 1 in series × 1 parallel | 20 V | 9.8 A | 18.0 A |
| 2 in series × 1 parallel | 41 V | 9.8 A | 18.0 A |
| 4 in series × 1 parallel | 82 V | 9.8 A | 18.0 A |
| 1 in series × 2 parallel | 20 V | 19.6 A | 35.9 A |
| 2 in series × 2 parallel | 41 V | 19.6 A | 35.9 A |
| 1 in series × 4 parallel | 20 V | 39.2 A | 71.9 A |
Max distance for one string at 2%
| Wire | 1 panel | 2 in series | 4 in series |
|---|---|---|---|
| 14 AWG | 6 ft | 13 ft | 26 ft |
| 12 AWG | 10 ft | 21 ft | 42 ft |
| 10 AWG | 16 ft | 33 ft | 67 ft |
| 8 AWG | 26 ft | 53 ft | 107 ft |
| 6 AWG | 42 ft | 85 ft | 170 ft |
Copper, at Vmp and Imp, one way.
Common questions
Series or parallel?
Series raises voltage and keeps current low, so the wire can be smaller and run farther. Use parallel when shading is a problem or the charge controller's input voltage limit is low.
Related calculators
Sources
- NFPA 70, National Electrical Code, 2023 edition (https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70)
- https://www.nrel.gov/pv/