Pool pumps are motors, sized from the NEC full-load current table rather than the nameplate. Pick the horsepower, voltage and distance.
Pump circuit
Fill in the circuit, then press the button.
Single-phase pumps at 230 V
| HP | FLC | Wire (125%) | Max breaker (250%) |
|---|---|---|---|
| 3/4 HP | 6.9 A | 14 AWG | 20 A |
| 1 HP | 8 A | 14 AWG | 20 A |
| 1-1/2 HP | 10 A | 14 AWG | 25 A |
| 2 HP | 12 A | 14 AWG | 30 A |
| 3 HP | 17 A | 10 AWG | 45 A |
Pool-specific rules
- GFCI protection for pool pump motors on 120 V through 240 V circuits (680.21(C)).
- An insulated copper equipment ground no smaller than 12 AWG (680.21(A)).
- The pump is bonded to the pool's equipotential bonding grid with 8 AWG solid copper (680.26).
Common questions
Can I run a pool pump on 115 V?
Small pumps can be wired for either. At 230 V the current halves, which allows smaller wire and much longer runs.
Related calculators
Sources
- NFPA 70, National Electrical Code, 2023 edition (https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70)