Pool pumps are motors, sized from the NEC full-load current table rather than the nameplate. Pick the horsepower, voltage and distance.

One way from the panel to the motor. Enter 0 to skip voltage drop.
%
Used for voltage drop. Leave blank to use the NEC table current.
A

Pump circuit

Fill in the circuit, then press the button.

Single-phase pumps at 230 V

HPFLCWire (125%)Max breaker (250%)
3/4 HP6.9 A14 AWG20 A
1 HP8 A14 AWG20 A
1-1/2 HP10 A14 AWG25 A
2 HP12 A14 AWG30 A
3 HP17 A10 AWG45 A

Pool-specific rules

  • GFCI protection for pool pump motors on 120 V through 240 V circuits (680.21(C)).
  • An insulated copper equipment ground no smaller than 12 AWG (680.21(A)).
  • The pump is bonded to the pool's equipotential bonding grid with 8 AWG solid copper (680.26).

Common questions

Can I run a pool pump on 115 V?

Small pumps can be wired for either. At 230 V the current halves, which allows smaller wire and much longer runs.