EV charger wire size calculator
Enter the charger's maximum current setting and the distance from the panel. The calculator applies the 125% continuous-load rule and checks voltage drop.
EV charger circuit
Fill in the circuit, then press the button.
Level 2 charger circuits
| Charger | Breaker | Copper (75 °C) | NM-B (60 °C) | Aluminum |
|---|---|---|---|---|
| 16 A | 20 A | 12 AWG | 12 AWG | 10 AWG |
| 24 A | 30 A | 10 AWG | 10 AWG | 8 AWG |
| 32 A | 40 A | 8 AWG | 8 AWG | 8 AWG |
| 40 A | 50 A | 8 AWG | 6 AWG | 6 AWG |
| 48 A | 60 A | 6 AWG | 4 AWG | 4 AWG |
| 64 A | 80 A | 4 AWG | 3 AWG | 2 AWG |
| 80 A | 100 A | 3 AWG | 1 AWG | 1 AWG |
Common questions
Can I put an EV charger on a 30 A dryer circuit?
Only at 24 A or less, and only if the dryer is not on it. Some chargers share a circuit through a listed load-sharing device.
Related calculators
Sources
- NFPA 70, National Electrical Code, 2023 edition (https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70)
- https://afdc.energy.gov/fuels/electricity-infrastructure-development