30 amp RV outlet wire size
A 30 A RV hookup is a single 120 V circuit on a NEMA TT-30 receptacle. 10 AWG copper is the minimum, but runs to a driveway pad are often long enough to need 8 or 6 AWG.
Wire size
Fill in the circuit, then press the button.
Wire by distance at 24 A
| Wire | 3% max | 5% max |
|---|---|---|
| 10 AWG | 60 ft | 100 ft |
| 8 AWG | 96 ft | 160 ft |
| 6 AWG | 152 ft | 254 ft |
| 4 AWG | 243 ft | 405 ft |
Don't miswire TT-30
A TT-30 receptacle is 120 V only. Wiring it to 240 V destroys RV electronics. Use a 30 A single-pole breaker, and GFCI protection where 210.8 requires it outdoors.
Common questions
Can I use a 30 A dryer outlet for my RV?
No. A dryer outlet supplies 240 V; the RV expects 120 V on a TT-30 plug.
Related calculators
Sources
- NFPA 70, National Electrical Code, 2023 edition (https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70)