Wall Oven wire size

Single wall ovens usually need a 30 A, 240 V circuit; double ovens 40 to 50 A. Enter the nameplate rating.

V
One way from the panel. Enter 0 to skip voltage drop.
%

Circuit

Fill in the circuit, then press the button.

By nameplate kW at 240 V

NameplateAmpsBreakerCopper (60 °C)Copper (75 °C)
3.6 kW15.0 A15 A14 AWG14 AWG
4.8 kW20.0 A20 A12 AWG12 AWG
6.0 kW25.0 A25 A10 AWG10 AWG
7.2 kW30.0 A30 A10 AWG10 AWG
8.0 kW33.3 A35 A8 AWG8 AWG

Demand factors

For the branch circuit, NEC 210.19(A)(3) lets a single wall oven or cooktop use its nameplate rating; for a counter-mounted cooktop and up to two wall ovens on one circuit, add their nameplates and treat them as one range under 220.55. Installation manuals usually name the exact breaker; use it.

Common questions

What size wire for a wall oven on a 30 A breaker?

10 AWG copper in NM-B or 10 AWG THHN with 75 °C terminals.

Sources

  • NFPA 70, National Electrical Code, 2023 edition (https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70)