Voltage Drop Calculator

HomeDC & solar

Car amplifier wire size

Amp current depends on its RMS output and efficiency. Class D amps are around 80% efficient, class AB around 60%. Enter the total RMS watts.

W
Battery to amp, one way.
80% for class D, 60% for class AB.
%
%

Power wire

Fill in the circuit, then press the button.

Power wire by RMS watts, 17 ft

RMS wattsCurrent (class D)Wire
300 W27 A4 AWG
500 W45 A3 AWG
800 W72 A1 AWG
1,000 W91 A1/0 AWG
1,500 W136 A3/0 AWG
2,000 W181 A4/0 AWG
3,000 W272 A300 kcmil

Copper (not CCA), 13.8 V running voltage, 90 °C ampacity at 125%, 3% drop.

CCA vs OFC

Copper-clad aluminum cable has roughly 1.5 times the resistance of copper of the same gauge. If you use CCA, go up about two sizes.

Common questions

Do I need the same gauge ground wire?

Yes. The ground carries the same current. Keep it short and bolted to bare metal.