Voltage Drop Calculator

HomeDC & solar

Winch wire size

Winches pull 250 to 450 A at full load, but only for short bursts. Cable is sized for voltage drop, with the ampacity check turned off. Enter the winch's maximum current.

V
A
One way. The wire runs out and back.
%

Cable size

Fill in the circuit, then press the button.

Cable by amps and length, 10% drop

Current4 ft6 ft8 ft10 ft15 ft20 ft
200 A6 AWG6 AWG4 AWG3 AWG2 AWG1/0 AWG
250 A6 AWG4 AWG3 AWG2 AWG1 AWG2/0 AWG
300 A6 AWG4 AWG3 AWG2 AWG1/0 AWG2/0 AWG
350 A4 AWG3 AWG2 AWG1 AWG2/0 AWG3/0 AWG
400 A4 AWG3 AWG1 AWG1/0 AWG2/0 AWG4/0 AWG
450 A4 AWG2 AWG1 AWG1/0 AWG3/0 AWG4/0 AWG

10% is a common allowance for winches because they run for seconds at a time. Shorter cables and heavier gauge mean more pulling power.

Install notes

Winch makers supply or specify cable lengths and gauges; follow them. Rear-mount and trailer winches with long cables often need 1/0 or 2/0.

Common questions

Can I extend my winch cables?

Yes, if the extension uses a size that keeps total drop acceptable. Each foot of 2 AWG at 400 A drops about 0.16 V out and back.